{"id":392,"date":"2026-11-06T21:32:00","date_gmt":"2026-11-06T13:32:00","guid":{"rendered":"https:\/\/kerkepm.com\/knowledge\/extruder-energy-consumption\/"},"modified":"2026-11-08T20:42:59","modified_gmt":"2026-11-08T12:42:59","slug":"extruder-energy-consumption","status":"publish","type":"page","link":"https:\/\/kerkepm.com\/es\/knowledge\/extruder-energy-consumption\/","title":{"rendered":"Extruder Energy Consumption"},"content":{"rendered":"<div class=\"k3\">\n<div class=\"wrap\"><div class=\"crumbs\"><a href=\"\/\">Home<\/a><span>\/<\/span><a href=\"\/knowledge\/\">Knowledge<\/a><span>\/<\/span>Extruder Energy Consumption<\/div><\/div><div class=\"wrap\"><div class=\"hero\">\n<p class=\"kicker\">Process \u00b7 5 min read<\/p>\n<h1>Extruder Energy Consumption: kWh per kg, and Where It Goes<\/h1>\n<p class=\"dek\">Specific energy for compounding typically lands between 0.12 and 0.35 kWh\/kg. This article shows which of the two ends you are on, and what actually moves the number. A reference extruder energy consumption page from Kerke.<\/p>\n<div class=\"byline\"><div><b>Updated<\/b> 6 November 2026<\/div><div><b>Reviewed by<\/b> Kerke process team<\/div>\n<div><b>Basis<\/b> commissioning records, parameter table<\/div><\/div>\n<\/div><\/div>\n<div class=\"wrap\"><div class=\"grid\"><main>\n\n<p class=\"lead\">Energy is 5\u201312% of conversion cost, which is small until you run 6,000 hours a year. The useful question is not 'how many kW is the motor' but 'how many kWh does a kilo cost at my filling level'.<\/p>\n\n<nav class=\"wp-block-rank-math-toc-block k3-toc\" aria-label=\"On this page\"><b>On this page:<\/b><a href=\"#rm-s1\">Benchmarks<\/a><a href=\"#rm-s2\">The four levers that move it<\/a><a href=\"#rm-s3\">A quick calculation<\/a><a href=\"#rm-s4\">Induction heating, honestly<\/a><a href=\"#rm-s5\">FAQ<\/a><\/nav><h2 class=\"sec\" id=\"benchmarks\" id=\"rm-s1\">Benchmarks<\/h2>\n<div class=\"tw\"><table>\n<caption><b>Table 2.<\/b> Specific energy by application (motor input, barrel heating excluded).<\/caption>\n<thead><tr><th scope=\"col\">Application<\/th><th scope=\"col\">kWh\/kg<\/th><th scope=\"col\">Why<\/th><\/tr><\/thead>\n<tbody>\n<tr><td>Filler masterbatch 80%<\/td><td class=\"num\">0.10\u20130.16<\/td><td>Filler is easy to convey and needs little melting energy.<\/td><\/tr>\n<tr><td>Colour masterbatch<\/td><td class=\"num\">0.18\u20130.28<\/td><td>Dispersion work dominates; pigment loading is low.<\/td><\/tr>\n<tr><td>Glass fibre reinforced PA<\/td><td class=\"num\">0.22\u20130.35<\/td><td>High torque, high temperature, side-feed compression work.<\/td><\/tr>\n<tr><td>PET recycling<\/td><td class=\"num\">0.15\u20130.22<\/td><td>Drying and devolatilization dominate the energy bill.<\/td><\/tr>\n<tr><td>PVC compound (two-stage)<\/td><td class=\"num\">0.12\u20130.18<\/td><td>Low temperature, low shear by design.<\/td><\/tr>\n<\/tbody><\/table><\/div>\n\n<h2 class=\"sec\" id=\"levers\" id=\"rm-s2\">The four levers that move it<\/h2>\n<ul>\n<li><strong>Run near rated output.<\/strong> Specific energy at 50% output is 20\u201340% higher than at 90%; the motor and gearbox losses are nearly constant.<\/li>\n<li><strong>Do not over-mix.<\/strong> Every extra kneading block adds 3\u20136% to specific energy. If dispersion tests pass at 40D, 48D is a donation to the electricity supplier.<\/li>\n<li><strong>Insulate the barrel.<\/strong> Barrel heating is 15\u201325% of total energy on a cold shop floor; insulation pays back in about a year.<\/li>\n<li><strong>Check the water circuit.<\/strong> A fouled heat exchanger raises pelletizer and chiller load without showing up in extruder data.<\/li>\n<\/ul>\n\n<h2 class=\"sec\" id=\"calculate\" id=\"rm-s3\">A quick calculation<\/h2>\n<p>Motor 110 kW, average load 72%, output 420 kg\/h \u2192 110 \u00d7 0.72 \u00f7 420 = <strong>0.19 kWh\/kg<\/strong>. At 6,000 h\/year and 0.10 USD\/kWh, that is 479,000 kWh and 47,900 USD a year. A 10% improvement \u2014 mostly from running at higher output and removing one mixing block \u2014 is 4,800 USD a year per line.<\/p>\n\n<h2 class=\"sec\" id=\"induction\" id=\"rm-s4\">Induction heating, honestly<\/h2>\n<p>Induction barrel heaters save 20\u201330% of <em>heating<\/em> energy, which is 4\u20137% of total energy \u2014 a real but modest number. They pay back faster on machines that run cold-start cycles than on lines that run continuously at high output.<\/p>\n\n<h2 class=\"sec\" id=\"faq\" id=\"rm-s5\">FAQ<\/h2>\n<details open><summary>How do I measure specific energy properly?<\/summary><p>Read motor input power from the drive for a full hour at steady state and divide by the weighed output. Using the nameplate kW gives a number that is 25\u201335% too high.<\/p><\/details><details><summary>Does higher screw speed reduce energy per kg?<\/summary><p>Up to a point: output rises faster than power. Beyond the point where melt temperature forces you to back off, it reverses.<\/p><\/details><details><summary>Is a two-stage line less efficient?<\/summary><p>Per kg it is comparable: two motors but less total shear work. The gain is stability at high filler, not kWh.<\/p><\/details>\n<div class=\"method\"><h2 id=\"rm-s6\">Where these numbers come from<\/h2>\n<p>Values are drawn from the Kerke parameter table, commissioning records and service reports from lines in the field. Temperature windows and consumption figures are typical ranges \u2014 confirm on your own material before they become a production setpoint.<\/p><\/div>\n<div class=\"related\"><h2 id=\"rm-s7\">Related reading<\/h2><div class=\"rel-grid\"><a class=\"rel\" href=\"\/knowledge\/twin-screw-extruder-size-chart\/\"><span>Knowledge<\/span>Twin Screw Extruder Size Chart: 16 mm to 135 mm, 1 to 4,000 kg\/h<\/a><a class=\"rel\" href=\"\/knowledge\/extruder-maintenance-schedule\/\"><span>Knowledge<\/span>Extruder Maintenance Schedule: 250 \/ 2,500 \/ 5,000 \/ 10,000 Hours<\/a><\/div><\/div>\n<div class=\"cta\"><div><b>Tell us your material \u2014 we will tell you the line<\/b><p>Send 25\u201350 kg and we run it on our lab extruder: pellets, running video and a capacity report back in 3\u20137 days.<\/p><\/div>\n<div class=\"acts\"><a href=\"\/get-a-quote\/\">Get a quote<\/a>\n<a class=\"alt\" href=\"\/get-a-quote\/#trial\">Send material for trial<\/a><\/div><\/div>\n<\/main>\n<aside><h5>On this page<\/h5><ol><li><a href=\"#benchmarks\">Benchmarks<\/a><\/li><li><a href=\"#levers\">The four levers that move it<\/a><\/li><li><a href=\"#calculate\">A quick calculation<\/a><\/li><li><a href=\"#induction\">Induction heating, honestly<\/a><\/li><li><a href=\"#faq\">FAQ<\/a><\/li><\/ol>\n<div class=\"sidecard\"><b>Question not covered?<\/b><p>Send the material, the machine model and the symptom. We answer with a parameter sheet, not a brochure.<\/p>\n<a class=\"btn\" href=\"\/get-a-quote\/\">Ask an engineer<\/a>\n<a class=\"btn ghost\" href=\"\/knowledge\/\">All articles<\/a><\/div><\/aside><\/div><\/div>\n<script type=\"application\/ld+json\">{\"@context\": \"https:\/\/schema.org\", \"@graph\": [{\"@type\": \"TechArticle\", \"headline\": \"Extruder Energy Consumption: kWh per kg, and Where It Goes\", \"description\": \"Specific energy for compounding typically lands between 0.12 and 0.35 kWh\/kg. This article shows which of the two ends you are on, and what actually moves the number.\", \"datePublished\": \"2026-11-06\", \"dateModified\": \"2026-11-06\", \"inLanguage\": \"en\", \"author\": {\"@type\": \"Organization\", \"name\": \"Kerke Extrusion Equipment\"}, \"mainEntityOfPage\": \"https:\/\/www.kerkepm.com\/knowledge\/extruder-energy-consumption\/\"}, {\"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"How do I measure specific energy properly?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Read motor input power from the drive for a full hour at steady state and divide by the weighed output. Using the nameplate kW gives a number that is 25\u201335% too high.\"}}, {\"@type\": \"Question\", \"name\": \"Does higher screw speed reduce energy per kg?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Up to a point: output rises faster than power. Beyond the point where melt temperature forces you to back off, it reverses.\"}}, {\"@type\": \"Question\", \"name\": \"Is a two-stage line less efficient?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Per kg it is comparable: two motors but less total shear work. The gain is stability at high filler, not kWh.\"}}]}]}<\/script>\n<div class=\"wrap\"><section class=\"k3-more\" id=\"rm-more\"><h2>Extruder energy consumption \u2014 the short version<\/h2><figure class=\"k3-fig\"><img decoding=\"async\" src=\"\/wp-content\/uploads\/2026\/11\/kte-65b-co-rotating-twin-screw-extruder-01-1200.webp\" alt=\"extruder energy consumption\" loading=\"lazy\" width=\"1200\" height=\"675\"><figcaption>Kerke test line, Nanjing \u2014 where the figures on this page were measured<\/figcaption><\/figure><p>Note on Extruder energy consumption: every figure on this page is a reference range measured on Kerke's own test line in Nanjing, not a catalogue maximum. If your material differs from the one in the table, send 25\u201350 kg and we will replace the range with a measured number.<\/p><p class=\"k3-rel\"><b>Related on this site:<\/b> <a href=\"\/machines\/co-rotating-twin-screw-extruder\/\">Twin screw extruder range<\/a> \u00b7 <a href=\"\/applications\/\">Extrusion lines by application<\/a> \u00b7 <a href=\"\/get-a-quote\/\">free extrusion line quotation<\/a> \u00b7 <a href=\"https:\/\/en.wikipedia.org\/wiki\/Pelletizing\" target=\"_blank\" rel=\"noopener\">Wikipedia: Pelletizing<\/a><\/p><\/section><\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Home\/Knowledge\/Extruder Energy Consumption Process \u00b7 5 min read Extruder Energy Consumption: kWh per kg, and Where It Goes Specific energy for compounding typically lands between 0.12 and 0.35 kWh\/kg. This article shows which of the two ends you are on, and what actually moves the number. A reference extruder energy consumption page from Kerke. Updated [&#8230;]\n","protected":false},"author":1,"featured_media":0,"parent":63,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"page-blank.php","meta":{"footnotes":""},"application":[],"app_group":[],"class_list":["post-392","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/kerkepm.com\/es\/wp-json\/wp\/v2\/pages\/392","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/kerkepm.com\/es\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/kerkepm.com\/es\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/kerkepm.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/kerkepm.com\/es\/wp-json\/wp\/v2\/comments?post=392"}],"version-history":[{"count":0,"href":"https:\/\/kerkepm.com\/es\/wp-json\/wp\/v2\/pages\/392\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/kerkepm.com\/es\/wp-json\/wp\/v2\/pages\/63"}],"wp:attachment":[{"href":"https:\/\/kerkepm.com\/es\/wp-json\/wp\/v2\/media?parent=392"}],"wp:term":[{"taxonomy":"application","embeddable":true,"href":"https:\/\/kerkepm.com\/es\/wp-json\/wp\/v2\/application?post=392"},{"taxonomy":"app_group","embeddable":true,"href":"https:\/\/kerkepm.com\/es\/wp-json\/wp\/v2\/app_group?post=392"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}